What are the requirements for the installation of condenser
Leave a message
When the differential pressure transmitter measures the flow rate, the condenser condenses the measured steam, and the condensate in the positive and negative pressure tubes has equal height and remains constant. To this end, the volume of the condenser should be 3 times the maximum volume of the working space of the differential pressure transmitter, and the horizontal cross-sectional area should not be less than the working area of the differential pressure transmitter, so as to ignore the condensate fluctuation or additional errors caused by condensation. Condensing the medium to avoid high temperature damage to the transmitter needs to meet the following installation requirements:
1, the height difference between the two condensers is not more than 2mm. The condensation tank is installed to ensure that the liquid temperature of the measuring pipe is consistent, so that it is not affected by the temperature change of the measuring medium, and to ensure that the condensing surface in the positive and negative pressure pipes has the same height and remains constant. When the differential pressure changes sharply, the measurement error will not occur.
2, the volume of the condensing tank should be greater than three times the maximum working volume change of the differential pressure instrument, and the cross-sectional area of the container is not less than the working area of the differential pressure instrument. If the condenser is mainly an ordinary isolation tank style, it is a buffer with increased area, the purpose is to speed up the cooling of the medium in the pressure tube after the pressure valve by increasing the surface area, so that it can adapt to the temperature measurement requirements of the transmitter nozzle, and prevent the high temperature medium from damaging the transmitter.
3, for the measured medium is easy to condense viscous medium, most of them are worried about the pressure tube plugging phenomenon after the condensation of the medium in the pressure tube, so most of the time do not use the condenser and increase the heat tracing measures. Condenser is the most common application in the measurement of steam, because steam is a high temperature and high pressure medium and easy to condense into water, in order to ensure that the transmitter measurement cartridge is not damaged by high temperature
4, in order to ensure that the pressure tube is all condensed water, to prevent the additional differential pressure value due to the different height of the condensate water in the two tubes, most of the condenser with the nature of the buffer tank is used as a condensation measure to accelerate the steam change into water, but considering the nature of the water in the pressure tube in winter, the heat tracking measure is also used.