How to prevent the evaporator from freezing

How to prevent the evaporator from freezing? The following is a simple popularization for everyone:

 

1, low voltage control switch

The key work of the low pressure control switch is to set the low pressure of the refrigerant and warn the external leakage of the refrigerant. When the system is running, the control switch senses that the intrinsic pressure is lower than the set pressure, and stops the operation of the shrinking machine to prevent the pressure from continuing to fall. When the evaporation pressure of the refrigerant is reduced, its relative saturated evaporation temperature is also reduced, and the possibility of forming ice on the ice water side is greatly increased, that is, the setting of the low-pressure control switch also has anti-freezing performance. If the refrigerant temperature is lower than 0 degrees and continues to run and stop, ice on the ice side is likely to cause the plate to burst.

 

2, refrigerant side antifreeze switch

The performance of antifreeze operation is the same as that of the low-pressure control switch, the difference is that the freezer switch is set by temperature rather than pressure, the refrigerant is the lowest part of the temperature in the freezing cycle system in the evaporator, if the temperature of the refrigerant can be controlled not less than 0 degrees, the ice water side is no danger of icing.


3, water side temperature control anti-freeze switch

When the plate heat exchanger is used in the evaporator, the control cold temperature is removed to prevent the water side from freezing, and the water temperature can also be directly controlled to prevent freezing. In the design, the outlet of the ice water side is equipped with temperature control and anti-freezing to control the temperature of the cooling circulating water. Attention: The temperature sensor should be installed at the outlet of the evaporator ice water. Because the water side is less lively than the cold side, the water temperature is usually controlled at more than 4 degrees, and the water temperature is lower than the set temperature.

 

4. Flow switch

The key function of the flow switch is to set the flow on the water side. When the water flow is lower than the set value, the system is closed to prevent the water from freezing in the heat exchanger, resulting in the heat exchanger splitting due to continuous freezing. Usually the cause of insufficient water will be formed, if the main pump is broken, the water pipe splits and leaks. The water pipe is under pressure. Water side pipeline obstruction, filter obstruction, ice sink no water and other factors. Insufficient water will cause the temperature difference of the inlet and outlet of the water side to increase, and the refrigerant evaporation temperature will drop. If the circulation continues, the temperature of the water side will drop lower and lower, and the insufficient water will cause the uneven distribution of the flow field, which will simply cause icing phenomenon in the low flow rate area.