How to maintain the condenser of low temperature constant temperature circulation device
Leave a message
The condenser in the high and low temperature constant temperature circulation device is one of the accessories in the refrigeration process. Its performance is very important. After a long time, the condenser needs regular maintenance, so how to maintain it?
The condensers used in the high and low temperature constant temperature circulation device group are divided into air-cooled condenser and water-cooled condenser. Air-cooled condenser is mainly used for air-cooled high and low temperature constant temperature circulation device, which takes air as cooling medium. Because there is often dust or other debris in the air, some of these dust or debris will fall on the outer surface of the condenser fin, which will make the heat dissipation effect of the condenser worse over time, especially in the place with bad environment. Therefore, we should clean it regularly. The cleaning method for the condenser of air-cooled high and low temperature constant temperature circulation device is: simple dust can be blown clean with compressed air, or vacuum cleaner. If there is more dirt on the fin condenser, gasoline or non-corrosive cleaning agent can be used to clean the heat dissipation pipe and fin, or tap water can be poured through and rinsed clean, so as to improve the heat dissipation effect.
There may also be some high and low temperature cycle units using casing water cooled condensers, which can be pickled. The operation method is to remove the condenser, release the water inside, and then inject 10% dilute sulfuric acid solution into the tube of the condenser until the solution flows out of the water outlet. Dilute sulfuric acid can be released after staying in the condenser for 20 ~ 30min. Repeat this action two or three times, and then install the connection pipe between the cooling water pipe and the condenser, open the cooling water valve and rinse for 10 ~ 20min. The scale prevention and cleaning work will end, and the scale prevention and cleaning work should be unremitting.
Water-cooled condenser is mainly used for water-cooled high and low temperature constant temperature circulation device. For this condenser, it is mainly the problem of removing scale. Its cleaning cycle is generally based on water quality. If it is landscape and deep well water with poor water quality, it should be cleaned at least once every six months. If it is good water quality, such as pure water, it can be cleaned once a year. Some areas have catkins every spring and must be cleaned up in time.