Precautions for the use of stainless steel finned evaporator!
Leave a message
Precautions for the use of stainless steel finned evaporator! Stainless steel finned evaporator is widely used in medicine, food, chemical, light industry and other industries of water or solution evaporation concentration, in addition to these can be used, in fact, it can be widely used in the above industries of wastewater treatment. It has many advantages such as high evaporation capacity, energy saving and low operating cost. Here are the precautions for stainless steel finned evaporator.
In the use of stainless steel finned evaporator, it should be noted that if the temperature continues to rise, first check whether the vacuum trip, then check whether the condensate is not discharged, and then check whether the steam pressure suddenly rises, whether it may leak. Stop and maintain pressure to determine the problem. The top heater shall be equipped with a safety valve. The steam pressure in the top heater shall not exceed 0.01Mpa. Check the safety valve for frequent failures. Don't be careless. In any case, the steam valve should be closed when stopped. When the evaporator circulation pump stops running due to failure, the steam should be turned off immediately. This product operates by connecting multiple evaporators.
The secondary steam produced by evaporation in the former evaporator is used as heating steam in the latter evaporator. As a result, heat energy can naturally be reused many times and heat consumption can be significantly reduced. Stainless steel finned evaporators can also be used for large-scale industrial production, which usually requires the evaporation of a large amount of water, which requires a lot of energy to heat the water to produce steam. In order to reduce the consumption of heating steam, multi-effect evaporation can be used. In the actual use of stainless steel finned evaporator, stainless steel finned evaporator should pay attention to pressure stability and frequent observation; The vacuum degree and temperature meet the requirements, especially under negative pressure operating conditions. If you notice any fluctuations, find the cause immediately.
Adjust the discharge valve of the stainless steel finned evaporator so that the discharge proportion meets the requirements and is measured regularly. When the equipment is unstable, it should be measured frequently; Under normal circumstances, there shouldn't be much change; When the temperature is found to rise rapidly, it immediately closes the steam valve to see if the vacuum pump is tripping. If yes, you can close the inlet valve of the vacuum pump. If there is no jump, check the status and wait for the temperature to drop before starting. In addition, we also need to adjust the feed valve to make the liquid level in the middle of the mirror stable. The vacuum pump, circulating pump, and condensate pump are running properly.
It should also be noted here that if the temperature continues to rise, first check whether the vacuum of the stainless steel finned evaporator is trip, and then check whether the condensate is not discharged, no problem, check whether the steam pressure suddenly rises, whether it may leak. It is recommended that you stop to maintain pressure to determine the problem. If the temperature of the stainless steel finned evaporator rises rapidly, close the steam valve immediately and check whether it is tripped. If so, close the intake valve. If there is no jump, check the status and wait for the temperature to drop.